Lightweight Concrete Reduces Weight and Increases Span Length of Pretensioned Concrete Bridge Girders

Karl Meyer, Lawrence F. Kahn

PCI Journal · 2002 · 27 citations · 2 references

Concepts

Abstract

The maximum length for simple span pretensioned concrete composite girder bridges using high strength lightweight concrete (HSLWC) were investigated analytically using concrete strengths of 8, 10, and 12 ksi (55, 60, and 83 MPa) and prestressing strands of 0.5 in. (15.2 mm) diameter. The use of HSLWC produced spans up to 4 percent longer than the same section made with high strength normal weight concrete (HSNWC). Based on the AASHTO I-girder and AASHTO PCI bulb tee sections examined in this study, the reduced girder weight eliminated the need for special transportation superload permits. Modified AASHTO-PCI bulb tees with one extra row of strands in the bottom flange extended the girders' maximum span length by at least 10 ft (3.1 m). Overall. the advantages of lightweight concrete with compressive strengths up to 12 ksi (83 MPa) include lower girder weight, relief from special permitting requirements, and longer span lengths.