Journal of Hand Surgery (European Volume) · 2011 · 11 citations · 12 references
MedicineOrthopaedic SurgeryOrthopedic SurgeryBiomechanicsOrthopedic BiomechanicsOrthopedicsBone MechanicsFixation BiomechanicsFracture BiomechanicsFracture FixationFracture MechanicsScapular FracturesBiomechanics Of Fixation ConstructsExperimental Study DesignFixation Construct BiomechanicsFracture Fixation BiomechanicsKirschner Wire FixationScapular Body FracturesWire Fixation Design
We have studied the biomechanical stability in vitro of three different Kirschner (K) wire configurations in three types of simulated scaphoid waist fractures. The fractures were created with a saw in Sawbones models. There were three fracture patterns: perpendicular to the long axis of the scaphoid model; and 30° and 20° oblique to that. Two 1.2 mm. K-wires were used in each scaphoid. The three configurations were: parallel; 20° oblique; and crossing. The oblique or crossing configurations of K-wires were the most stable depending on the fracture pattern.
12
Optimizing Bone Screw Pullout Force
Thomas A. DeCoster, David B. Heetderks, Daniel J. Downey et al. · Journal of Orthopaedic Trauma · 1990 · 212 citations
A biomechanical comparison of scaphoid screws
J. Shaw · The Journal Of Hand Surgery · 1987 · 71 citations