Radiology · 1975 · 31 citations · 0 references
MedicineRadiologyDiagnostic ImagingUltrasonographyUltrasoundBreast ExaminationBreast ImagingBreast PathologyBreast UltrasonographyBreast UltrasoundMammary TumorsBenign Breast Disease EvaluationBenign DiagnosisBenign Lesion DifferentiationBreast Lesion DiagnosisBreast Mass AssessmentDiagnostic Accuracy StudiesDiagnostic Breast UltrasoundSolid Mass Evaluation
Of 210 pathologically confirmed palpable breast masses examined by continuous ultrasound B-scanning using a 2.5- or 7-MHz transducer and mammography, fluid filled cysts more than 1 cm in diameter were diagnosed accurately in 75 cases. Of the 103 solid masses studied by echography, 31 were circumscribed (29 benign fibroadenomas and 2 circumscribed medullary carcinomas) and 72 were not. Infiltrating carcinoma represented the majority of the latter type, although 2 cases of chronic inflammation had the same echographic appearance. Thirty palpable breast masses less than 2 cm in diameter were not delineated with the 2.5-MHz transducer, and biopsy showed benign disease. The combiantion of mammography and continuous ultrasound B-scanning of palpable breast masses improved the diagnostic accuracy obtained with mammography alone and aided in the differentiation of nondiagnostic mammograms.