Publication | Closed Access
Onset of Resin Micro-cracks in Unidirectional Glass Fiber Laminates with Integrated SHM Sensors: Numerical Analysis
11
Citations
13
References
2009
Year
Numerical AnalysisEngineeringMicromechanicsMechanical EngineeringResin Micro-cracksPremature FailuresMechanicsSuch Embedded InclusionsContinuous-fibre CompositeSmart StructureMaterials ScienceComposite TechnologyFiber Optic SensingStructural Health MonitoringGlass FiberFiber-reinforced CompositeFailure LoadIntegrated Shm SensorsStructural Mechanics
The embedment of micro-sensors and micro-devices into composite laminates for structural health monitoring systems leads to stress/strain concentrations due to geometrical and material discontinuities around such embedded inclusions, with high potential to initiate premature failures. This article presents the efforts to estimate the effects of these stress/strain concentrations induced by the integration of rectangular-shape sensors within unidirectional fiber-glass composites. The micro-crack initiation sites and the failure load are predicted using finite-element simulations. Good agreement has been found between the numerical results and the experimental findings presented in an accompanying paper.
| Year | Citations | |
|---|---|---|
Page 1
Page 1