Journal of Hand Surgery (European Volume) · 2001 · 32 citations · 5 references
MedicineOrthopaedic SurgerySurgeryPain ManagementPain MedicineWound HealingSuturing InstrumentsWound ClosureWound Healing ResponseWound InflammationBony Tunnel DecompressionCarpal Tunnel Syndrome TherapyPolypropyleneSubcuticular SuturingSuture Anchor Materials
This randomised prospective clinical study compared the use of an absorbable suture (subcuticular 4:0 polyglactin 910) and a non-absorbable suture (5:0 monofilament polypropylene) for elective carpal tunnel decompression wound closure. An increased perception of pain was reported by the patients in the polypropylene (Prolene) group. At the 6-week assessment, there was a higher level of residual wound inflammation in the polyglactin 910 (Vicryl) group.