American Journal of Roentgenology · 1984 · 114 citations · 7 references
MedicineRadiologyUrologyDiagnostic RadiologyGenitourinary RadiologyUrolithiasisComputed TomographyCystine StonesStruvite StonesUreteral ImagingUric Acid StonesUrinary Stone CompositionCalcium Stone ImagingDensityHeterogeneityImaging Of Cystine StonesStone Composition EstimationStone Density MeasurementUric Acid CrystalsUrinary Calculi
Excised urinary calculi were subjected to computed tomographic (CT) scanning in an attempt to determine whether CT attenuation values would allow accurate analysis of stone composition. The mean, maximum, and modal pixel densities of the calculi were recorded and compared; the resulting values reflected considerable heterogeneity in stone density. Although uric acid and cystine calculi could be identified by their discrete ranges on one or more of these criteria, calcium-containing stones of various compositions, including struvite, could not be distinguished reliably. CT analysis of stone density is not likely to be more accurate than standard radiography in characterizing stone composition in vivo.
7
The unreliability of CT numbers as absolute values
Christopher Levi, JE Gray, EC McCullough et al. · American Journal of Roentgenology · 1982 · 242 citations
Computed tomography of urinary calculi
MP Federle, J W McAninch, JA Kaiser et al. · American Journal of Roentgenology · 1981 · 108 citations · Full text
Diagnosis of Nonopaque Calculi by Computed Tomography
Arthur J. Segal, Robert F. Spataro, Charles A. Linke et al. · Radiology · 1978 · 66 citations
Diagnostic value of CT numbers in pelvocalyceal filling defects.
R Parienty, R Ducellier, Julie Pradel et al. · Radiology · 1982 · 63 citations
The Analysis of Urinary Calculi
Joshua Kirby, C. F. Pelphrey, J. R. Rainey · American Journal of Clinical Pathology · 1957 · 26 citations