Arthroscopy The Journal of Arthroscopic and Related Surgery · 1996 · 55 citations · 17 references
MedicineOrthopedic SurgerySurgeryOrthopedicsReconstructive SurgeryShoulder SurgeryArthroscopic SurgeryEndoscopic SurgeryLigament InjuriesLigament ReconstructionTendon ReconstructionCruciate Ligament SurgeryIntra-articular Reconstruction
Interference screws are commonly used for graft fixation in bone-tendon-bone patellar tendon anterior cruciate ligament (ACL) reconstruction. The clinical significance of graft screw divergence has not been well studied. This report retrospectively reviews our initial experience in 73 consecutive endoscopic (single-incision) ACL reconstructions using interference screw fixation. Femoral divergence occurred more frequently in the lateral plane (29%) than the anteroposterior (AP) plane (15%). No early graft failures were noted clinically or by KT-1000 arthrometer testing. If properly tested at the time of operation, it does not appear that divergence of femoral screws < 30 degrees leads to early clinical failure in endoscopic ACL reconstruction. We propose that stresses on the graft-screw-tunnel construct will concentrate distally when placed in a divergent fashion, resulting in a wedge effect. No changes in early range of motion protocols or rehabilitation are recommended if screw divergence is noted and provided intraoperative stability is noted.
17
Instrumented measurement of anterior laxity of the knee.
Dale M. Daniel, Lawrence Malcom, Gary M. Losse et al. · Journal of Bone and Joint Surgery · 1985 · 750 citations
Anterior Cruciate Ligament Graft Fixation
Mark E. Steiner, Aaron T. Hecker, Charles H. Brown et al. · The American Journal of Sports Medicine · 1994 · 398 citations