British Journal of Radiology · 1997 · 13 citations · 8 references
MedicinePediatricsRadiologyRadiation DosimetryRadiation ProtectionRadiation SafetyDose PrescriptionPatient Radiation SafetyPediatric FluoroscopyPersonnel DosimetryRadiation Exposure In ChildhoodRadiation Risk AssessmentFluoroscopy Dose ReductionMedical Imaging Radiation DosePediatric DosimetryRadiation Dose ManagementRadiation Dose ReductionRadiation Safety In ChildrenRadiation Safety In FluoroscopyThermoluminescent Dosimeters
The aim of this study was to confirm that the radiation doses received by attendants who manually restrain infants during fluoroscopic procedures are low. Doses to the hands and neck of three radiologists and three nurses performing or assisting at all the fluoroscopic procedures in a children's hospital were measured for 1 month using thermoluminescent dosemeters. All fluoroscopy on children at this hospital is performed without an antiscatter grid. Total doses for the neck ranged from 20 to 50 microSv per week and for hands from 40 to 210 microSv per week. These doses were shared by the three radiologists and the three nurses. Individual doses received per staff member are very small when compared with the doses received by interventional radiology staff. Doses received by staff in this study were of the order of 5% of the limit advised by the National Health and Medical Research Council of Australia (NHMRC) for radiation workers. Nurses received larger doses than radiologists and steps will be taken to reduce this dose further.
8
An investigation of the radiation dose to staff during cardiac radiological studies
S. P. Jeans, K. Faulkner, H. G. Love et al. · British Journal of Radiology · 1985 · 62 citations
Medicine, Cardiology, Radiology +17