Nuclear Medicine Communications · 2004 · 118 citations · 17 references
MedicineNuclear MedicineRadiologyDiagnostic ImagingDiagnostic Nuclear MedicineDiagnostic RadiologyComputed TomographyNuclear Medicine ImagingRadioiodine TherapyThyroid CancerThyroid ImagingThyroid ScintigraphyDifferentiated Thyroid Cancer DiagnosisDifferentiated Thyroid Cancer ImagingIodine-131 ScintigraphyIodine-131 Therapy ImagingRadionuclide Thyroid ImagingRadionuclide Thyroid ScintigraphyThyroid Scan InterpretationThyroid Tumor Imaging
AIM: To determine the value of single photon emission computed tomography (SPECT) with integrated low-dose computed tomography (CT) for the interpretation of inconclusive foci in planar I whole-body scans after radioiodine therapy. METHODS: Twenty-five patients with inconclusive findings in planar scanning after ablative radioiodine therapy (3.7 GBq I) due to differentiated thyroid cancer were included. SPECT/CT of the region in question was performed with the Millennium VG Hawkeye (GE Medical Systems). SPECT with and without CT fusion were evaluated by two blinded independent nuclear medicine physicians in a consensus reading (including visual plausibility control). Each focus was judged according to its topographical assignment and clinical interpretation. With regard to therapeutic relevance, this information was evaluated in a focus based and patient based analysis. All evaluations used a binary ranking system. Focus assignments were compared to clinical and imaging follow-up. RESULTS: Forty-one lesions were observed in 25 patients. According to follow-up, 17/41 (41%) foci were caused by thyroid residue, 13/41 (32%) were caused by metastases, and 11/41 (27%) were not malignant. Of these foci, a SPECT/CT consensus reading assigned 39 (95%) correctly, as fused images of two foci did not pass the visual plausibility control (excluding one patient due to misregistration). For the remaining 39 foci, improved anatomical assignment by SPECT/CT was seen in 17/39 (44%) cases. CONCLUSIONS: The changed interpretation of 15/39 (38%) foci would have been relevant for therapy in the focus based analysis. In the patient based analysis the information was still therapeutically relevant in 6/24 (25%) patients. Furthermore, plausibility control is also crucial in SPECT/CT image fusion in order to rule out artifacts.
17
Follow-up of women with breast cancer: comparison between MRI and FDG PET
Gerhard W. Goerres, Sven Michel, Mathias K. Fehr et al. · European Radiology · 2002 · 156 citations
PET/CT of the abdomen: optimizing the patient breathing pattern
Gerhard W. Goerres, Cyrill Burger, Michael R. Schwitter et al. · European Radiology · 2003 · 124 citations