Measurements of pulmonary mechanics prior to the elective extubation of neonates

Michael J. Balsan, Judith Jones, Jon F. Watchko, Robert D. Guthrie

Pediatric Pulmonology · 1990 · 66 citations · 20 references

Concepts

TL;DR

The study proposes that measuring pulmonary mechanics, especially respiratory system compliance, can identify infants at risk of extubation failure. The authors measured respiratory system compliance and resistance using a passive expiratory flow technique in 61 neonates with respiratory distress syndrome before elective extubation. Higher respiratory system compliance and lower resistance were associated with successful extubation, with compliance ≥1.3 mL/cm H₂O predicting success in 94 % of infants and compliance ≤0.9 mL/cm H₂O predicting failure. Published in Pediatr Pulmonol 1990; 9:238–243.

Abstract

Abstract We measured total respiratory system compliance (C RS ) and resistance (R RS ) by the passive expiratory flow technique prior to the elective extubation of 61 neonates with a history of respiratory distress syndrome. Successful trials of extubation were characterized by a higher mean value of C RS when compared to trials that led to reintubation (1.52 vs. 1.10 mL/cm H 2 O, P = 0.004). Low values of C RS (0.9 mL/cm H 2 O or less) were invariably associated with extubation failure, whereas high values of C RS (1.3 mL/cm H 2 O or greater) were associated with extubation success in 94% of patients. A higher mean value of R RS was recorded in the group of infants who failed extubation when compared to those who were successful (0.22 vs. 0.17 cm H 2 O/mL/s, P = 0.042). We propose that measurements of pulmonary mechanics, particularly C RS , may by useful in identifying infants who will be at risk for extubation failure. Pediatr Pulmonal 1990; 9:238–243 .

References

20