Circulation · 1989 · 134 citations · 15 references
MedicineRadiologySurgeryCardiothoracic SurgeryDiagnostic ImagingDiagnostic RadiologyCardiac ImagingCardiovascular ImagingCoronary Artery ImagingCoronary Artery SurgeryMagnetic Resonance ImagingVascular ImagingBypass Graft Patency AssessmentCardiac Cine ImagingCine Magnetic Resonance ImagingCoronary Vascular ImagingGraft Imaging After Coronary Bypass SurgeryInterposition GraftsPulmonary Artery ImagingSpin Echo Imaging
Cine magnetic resonance imaging (MRI) is a gradient-recalled, retrospectively gated, fast-scan technique that depicts laminar flowing blood as bright signal and has been proposed as a useful method for determination of coronary artery bypass graft (CABG) patency. Therefore, we performed a blinded prospective study to assess the value of cine MRI determination of CABG patency in 20 patients with 45 CABG proximal anastomoses who were undergoing repeat angiography. Ten normal subjects served as controls to define normal intrathoracic vascular patterns. There were 21 left anterior descending (LAD) grafts, of which four were left internal mammary (LIMA), 12 left circumflex (Cx), and 12 right coronary (RCA) grafts. After localizing spin-echo coronal images were obtained, multiple axial multislice interleaved cine MRI acquisitions, each consisting of two to four 5-10-mm-thick slices at eight to 24 frames per cardiac cycle, were obtained from the superior main pulmonary artery to the inferior left ventricle. Each acquisition took 5-8 minutes with a subsequent 5-10 minutes of computer image reconstruction. Total study time per patient was 50-75 minutes. Known to cine MRI interpreters were the original surgical CABG insertions but not the angiographic findings. A graft was called patent if a bright graft flow signal, not corresponding to a normal vessel, was identified on multiple frames at multiple levels abutting the great vessels or epicardial surface of the heart. Angiographically, there were 33 patent grafts, of which 29 were identified as patent by cine MRI (sensitivity, 88%).(ABSTRACT TRUNCATED AT 250 WORDS)
15
Cine MR imaging: potential for the evaluation of cardiovascular function
Udo Sechtem, P W Pflugfelder, RG Gould et al. · American Journal of Roentgenology · 1987 · 251 citations
Medicine, Cardiology, Radiology +12
Magnetic resonance velocity mapping: clinical application of a new technique.
S. R. Underwood, David Firmin, R H Klipstein et al. · Heart · 1987 · 149 citations · Full text
Medicine, Cardiology, Radiology +17
Measurement of myocardial blood flow by ultrafast computed tomography.
C.J. Wolfkiel, James L. Ferguson, Eva V. Chomka et al. · Circulation · 1987 · 142 citations · Full text
Medicine, Cardiology, Radiology +17
Coronary artery bypass graft patency: noninvasive evaluation with MR imaging.
Richard D. White, Gary R. Caputo, Gunnard Modin et al. · Radiology · 1987 · 142 citations
Medicine, Cardiology, Surgery +17