Journal of Cataract & Refractive Surgery · 1990 · 70 citations · 3 references
MedicineOphthalmologySurgeryMicrosurgeryOcular AnatomyOphthalmic SurgeryAnterior Segment SurgeryCataract ManagementCataract SurgeryCorneal AnatomyCorneal BiomechanicsCorneal Shape ChangesCorneal Thickness ChangesCorneal Topography ChangesFinite Element Strain AnalysisIncision GeometryLocal DeformationStructural Integrity Testing
The effect of incision length, location, and shape on the structural integrity of the globe was examined using finite element analysis by comparing the radial deformation of the corneoscleral tissue adjacent to the incision. The results show that incision length had the greatest adverse effect, 12 mm incisions causing deformations an order of magnitude higher than the distension of the intact globe at 20 mm Hg. The least structural disturbance was produced by 3 mm scleral pocket incisions.
3
Analysis of the corneo-scleral shell by the method of direct stiffness
A. S. Kobayashi, Savio L‐Y. Woo, Carteret Lawrence et al. · Journal of Biomechanics · 1971 · 51 citations
Engineering, Anatomy, Bioengineering +13