Cardiovascular Research · 1967 · 114 citations · 10 references
MedicineCardiologyPhysiologyAnesthetic TechniquesElectrophysiologyStructural Heart DiseaseCardiac ArrhythmiasCardiac Conduction SystemCardiac PhysiologyCardiovascular PathophysiologyConduction DisordersElectrocardiographyAtrioventricular Node AnatomyAtrioventricular Node PhysiologySecond-degree Atrioventricular Block
Mechanisms of clinically known varieties of second degree A-V block were studied in isolated rabbit hearts, utilizing ultramicroelectrode techniques. Progressive A-V conduction delay in Wenckebach phenomenon was due mainly to depressed conduction within the A-V node, while Mobitz type 2 block was due to either block in or below His bundle or concealed re-excitation in the A-V junction. Two levels of block were demonstrated both in forward and retrograde A-V transmission.
10
Electrophysiology of the Heart.
Annals of Internal Medicine · 1960 · 1.3K citations
Medicine, Cardiology, Physiology +17
Physiologic Evidence for a Dual A-V Transmission System
Gordon K. Moe, James B. Preston, H. Burlington · Circulation Research · 1956 · 479 citations · Full text
Medicine, Cardiology, Physiology +17
Inhomogeneous conduction in the A-V node
Yoshio Watanabe, Leonard S. Dreifus · American Heart Journal · 1965 · 123 citations
Richard Langendorf, Alfred Pick · Circulation · 1956 · 121 citations · Full text
Medicine, Cardiology, Physiology +14