EngineeringPetroleum EngineeringDrillingDrilling EngineeringHydraulic EngineeringDrilling EquipmentDrilling FluidsDrilling HydraulicsPermeability AnalysisPermeability AssessmentPermeability EvaluationDifferential StickingDrilling Fluid PropertiesFluid Loss MechanismsHigh-temperature FiltrationLost CirculationOpen Hole Completion DesignOpen-hole CompletionStatic Fluid Loss
Abstract For the past nine years, the drilling industry has used the Permeability Plugging Apparatus (PPA) to assist in evaluating and resolving differential sticking and lost circulation problems which may arise while drilling depleted, weak or fractured zones. The increasing use of open hole completions in horizontal wells also means that more attention has to be paid to the cake forming properties of drilling fluids. The PPA is a high pressure, high temperature filtration device designed to evaluate fluid loss and "spurt loss" of drilling fluids under filtration conditions that more closely approximate those encountered downhole than the filter paper normally used. Although filtration occurs under static rather than dynamic conditions, pressures as high as 5000 psi (34,500 kPA) and temperatures of up to 500°F (260°C) may be investigated. The main feature of the PPA is the use of ceramic disks as the filtration medium. These are available in a wide range of porosities and permeabilities to match those properties of the formation much better than filter paper can. There are currently five PPA types with different pressure ratings that are in use in the laboratory and the field. In response to concern about the safe use of these devices, and the reproducibility of the data generated with them, the American Petroleum Institute initiated a program to investigate these issues, and to produce a standardized test procedure. The new API procedure addresses the safety issues of the PPA cell designs. Further, to provide consistency between users, the procedure outlines a new method of calculating spurt loss and total filtrate volume parameters based on the test data. The new procedure has been used, both in the laboratory and the field, to evaluate seepage loss additives as well as traditional lost circulation additives. Case histories are provided which demonstrate successful use of the device in evaluating lost circulation material and in the prevention of differential sticking problems while drilling depleted zones as well as designing pills for severe lost circulation.