International Journal of Cardiology · 2014 · 35 citations · 30 references
MedicineBiomedical EngineeringSurgeryBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyAblation TherapyAtrial FibrillationCatheter AblationMagnetic Resonance ImagingStrokeDiffusion-weighted ContrastPulmonary Microembolism ImagingPulmonary Vein ImagingPulmonary Vein Isolation
BACKGROUND: Clinically silent cerebral ischemia (SCI) detected by diffusion-weighted MRI has been reported in 5-40% of patients undergoing pulmonary vein isolation (PVI). Although initial reports suggested a high rate of SCI with phased radiofrequency (RF) ablation on use of the pulmonary vein ablation catheter (PVAC), the incidence was subsequently markedly reduced in consequence of procedural modifications in recent studies. We analyzed cerebral microembolization as assessed with transcranial Doppler during phased RF ablation and with two other single-shot AF ablation technologies: the cryoballoon (CB) and the nMARQ™ multipolar irrigated RF ablation system. METHODS AND RESULTS: A total of 89 patients (mean age: 57, SD: 12years; 62 males) with paroxysmal or persistent AF underwent PVI. Phased RF was used according to the initial protocol in 7 patients (PVAC Group I), with procedural modifications and a newer (14.4) version of the RF generator in 37 patients (PVAC Group II) and with the most recent (version 15.1) generator in 18 patients (PVAC Group III). Ablation was performed with the CB in 13 and with the nMARQ system in 14 patients. The number of microemboli (mean+(SD)) detected in the middle cerebral arteries was 2703 (918) in PVAC Group I, 1087 (542) in PVAC Group II, 719 (469) in PVAC Group III, 1057 (784) with CB and 2166 (1047) with nMARQ (p<0.01). CONCLUSION: Significant decreases in MES counts were observed thanks to the procedural modifications and newer RF generator with phased RF. High MES counts comparable to those with the initial phased RF resulted from the use of nMARQ.
30
Karl Heinz Kuck, Riccardo Cappato, Josép Brugada et al. · EP Europace · 2012 · 2.7K citations · Full text
Medicine, Cardiology, Surgery +11
Consensus on Microembolus Detection by TCD
E. Bernd Ringelstein, Dirk W. Droste, Viken L. Babikian et al. · Stroke · 1998 · 634 citations · Full text
Lower Incidence of Thrombus Formation With Cryoenergy Versus Radiofrequency Catheter Ablation
Paul Khairy, Patrick Chauvet, John W. Lehmann et al. · Circulation · 2003 · 515 citations
Medicine, Cardiology, Anesthesia +13
Radiofrequency Catheter Ablation of Atrial Fibrillation: A Cause of Silent Thromboembolism?
Fiorenzo Gaïta, Domenico Caponi, Martina Pianelli et al. · Circulation · 2010 · 358 citations · Full text
Medicine, Cardiology, Surgery +17