MedicineBiomedical EngineeringCardiologyBioinstrumentationClinical CardiologyElectrophysiologyAtrial FibrillationCardiac Conduction SystemCardiac PacingElectrocardiogram AnalysisElectrocardiographyVentricular ElectrophysiologyCardiac Monitoring SystemsCardiac Sensing DevicesElectrocardiographic Lead SystemsImplantable Cardioverter DefibrillatorsVentricular Arrhythmia MonitoringVentricular Fibrillation Detection
INTRODUCTION: The sensing performance of transvenous lead systems may be adversely affected by the delivery of high-energy shocks. This may be due to the proximity of the sensing and energy-delivery electrodes on transvenous leads. METHODS AND RESULTS: The time required for detection of ventricular fibrillation and redetection after a failed first shock was compared in 93 patients with five different lead system-pulse generator combinations: Cadence--Endotak 60 series, Ventak P--Endotak 60 series, Jewel--Transvene, Cadence--TVL, and Cadence--Transvene. A total of 418 successful and 204 failed first shocks were delivered during induced ventricular fibrillation. Redetection times (RED) were consistently shorter than detection times (DET) in the Jewel-Transvene (RED minus DET: -1.9 +/- 0.8 sec, P < 0.0001), the Cadence-TVL (-1.6 +/- 1.0 sec, P < 0.0001), and the Cadence-Transvene combinations (-2.0 +/- 0.9 sec, P < 0.0004). Redetection times were not significantly different than detection times in the Cadence-Endotak combination (0.9 +/- 3.1 sec; P = 0.09). Redetection times were significantly longer than detection times in the Ventak-Endotak combination (1.2 +/- 2.3 sec; P = 0.034). Prolonged individual redetection episodes (> 8.2 sec) were observed in the Cadence-Endotak (7 [10%] of 73 episodes) and the Ventak-Endotak (4 [10%] of 39 episodes), but not in the Jewel-Transvene, the Cadence-TVL, and the Cadence-Transvene combinations. CONCLUSIONS: Redetection of ventricular fibrillation may be delayed in some transvenous lead-pulse generator combinations. Successful redetection of ventricular fibrillation following a failed first shock should be demonstrated prior to hospital discharge of patients with implantable defibrillators.
13
Conduction disturbances caused by high current density electric fields.
Seitaro Yabe, W.M. Smith, James P. Daubert et al. · Circulation Research · 1990 · 156 citations · Full text
Medicine, Cardiology, Physiology +12
Francis E. Marchlinski, Belinda Flores, John M. Miller et al. · The American Journal of Cardiology · 1988 · 117 citations
Medicine, Cardiology, Surgery +9