Angiology · 1999 · 12 citations · 27 references
MedicineCardiologyNuclear MedicineCardiac Nuclear MedicineClinical CardiologyDiagnostic ImagingCardiac ImagingCardiac Nuclear ImagingCardiovascular ImagingCoronary Artery DiseaseCoronary Artery ImagingIschemic Heart DiseaseCardiac Metabolism ImagingCoronary Artery Disease DetectionCoronary Artery Disease ImagingCoronary Artery Stenosis AssessmentCoronary Lesion AssessmentCoronary Physiologic AssessmentCoronary Stenosis AssessmentIodine-123 Imaging
Iodine 123 beta-methyl iodophenyl pentadecanoic acid (123I-BMIPP), a beta-methyl-branched fatty acid analogue, has been proven by experimental studies to reveal abnormalities in fatty-acid-related metabolism. This study was undertaken to validate the accuracy and limitations of 123I-BMIPP imaging at rest in detecting myocardial metabolic abnormalities and predicting coronary lesions in unstable angina (UA). One hundred UA patients without prior myocardial infarction were studied. 123I-BMIPP and thallium 201 chloride (201TlCl) imaging with single photon emission computed tomography (SPECT) and coronary and left ventricular cineangiography (LVC) were performed 1 week after the last episode of angina. There was reduced uptake of 123I-BMIPP imaging in 70 patients, reduced uptake of 201TlCl in 41, and abnormal LVC contraction in 49 patients. There were significant increases in severity scores of 123I-BMIPP imaging along with increases in the number of stenosed coronary arteries and the severity of stenosis in individual coronary arteries. There was a significant reduction in 123I-BMIPP severity scores 1 month after percutaneous transluminal coronary angioplasty (p < 0.01) and a significant correlation between the severity scores of 123I-BMIPP and LVC (r=0. 579, p<0.001). Overall rates of sensitivity and specificity in detecting significant coronary stenosis by 123I-BMIPP imaging were 74% and 86%, respectively, whereas rates of sensitivity and specificity in detecting significant coronary stenosis by 201TlCl were 31% and 91%, respectively. 123I-BMIPP sensitivity increases to 86% if only advanced coronary stenosis of >90% is included. In conclusion, 123I-BMIPP myocardial imaging is an effective method of predicting coronary artery lesions of UA patients without provocative test.
27
Austen Wg, Je. Edwards, RL Frye et al. · Circulation · 1975 · 3.3K citations · Full text
Medicine, Cardiology, Surgery +17
Unstable angina. A classification.
Eugene Braunwald · Circulation · 1989 · 1.4K citations · Full text
Metabolism of the heart in health and disease. Part I
Lionel H. Opie · American Heart Journal · 1968 · 414 citations
Nagara Tamaki, Masahide Kawamoto, Yoshiharu Yonekura et al. · PubMed · 1992 · 189 citations