<sup>13</sup>C/<sup>12</sup>C ratios in CO<sub>2</sub> extracted from Antarctic ice

H. Friedli, Ernst Moor, H. Oeschger, U. Siegenthaler, B. Stauffer

Geophysical Research Letters · 1984 · 60 citations · 20 references

DOIFull text

Open access

Concepts

Abstract

Air is extracted from bubbles of polar ice samples by a dry extraction method, and the 13 C/ 12 C ratio is measured on CO 2 separated from the air. Ice samples of typically 700 g are crushed at ca. −20°C, the evolving air is trapped cryogenically, and CO 2 is frozen out from this air for mass‐spectrometric isotope analysis. First δ 13 C and δ 18 O results of CO 2 from Antarctic ice cores are presented, and δ 13 C is discussed in relation to atmospheric CO 2 variations. δ 13 C of 400 to 800 year old ice is ca. 1.1 %o higher than the 1980 atmospheric value, which agrees well with model‐based estimations. The measurement of three ca. 50,000 yr old samples yielded astonishingly low values, but contamination cannot be excluded.

References