Journal of Clinical Microbiology · 2012 · 203 citations · 26 references
Life SciencesInfectious DiseasesMicrobiologyBacteriologyDiagnostic MicrobiologyMedical MicrobiologyBloodstream InfectionsClinical BacteriologyDiagnostic BacteriologyMass SpectrometryMicrobial AnalysisPathogen DetectionBlood Culture BottlesIdentificationMaldi-tof IdentificationMaldi-tof Mass SpectrometryMatrix-assisted Laser Desorption/ionization Time-of-flight Mass SpectrometryMicrobiological Sample ProcessingRapid Blood Culture IdentificationTime-of-flight Mass Spectrometry
Matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry represents a revolution in the rapid identification of bacterial and fungal pathogens in the clinical microbiology laboratory. Recently, MALDI-TOF has been applied directly to positive blood culture bottles for the rapid identification of pathogens, leading to reductions in turnaround time and potentially beneficial patient impacts. The development of a commercially available extraction kit (Bruker Sepsityper) for use with the Bruker MALDI BioTyper has facilitated the processing required for identification of pathogens directly from positive from blood cultures. We report the results of an evaluation of the accuracy, cost, and turnaround time of this method for 61 positive monomicrobial and 2 polymicrobial cultures representing 26 species. The Bruker MALDI BioTyper with the Sepsityper gave a valid (score, >1.7) identification for 85.2% of positive blood cultures with no misidentifications. The mean reduction in turnaround time to identification was 34.3 h (P < 0.0001) in the ideal situation where MALDI-TOF was used for all blood cultures and 26.5 h in a more practical setting where conventional identification or identification from subcultures was required for isolates that could not be directly identified by MALDI-TOF. Implementation of a MALDI-TOF-based identification system for direct identification of pathogens from blood cultures is expected to be associated with a marginal increase in operating costs for most laboratories. However, the use of MALDI-TOF for direct identification is accurate and should result in reduced turnaround time to identification.
26
Suzanne Q. van Veen, Eric C. J. Claas, Ed J. Kuijper · Journal of Clinical Microbiology · 2010 · 656 citations · Full text
Alain Bizzini, Christian Durussel, Jacques Billé et al. · Journal of Clinical Microbiology · 2010 · 600 citations · Full text
Lindsay G. Stevenson, Steven K. Drake, Patrick R. Murray · Journal of Clinical Microbiology · 2009 · 425 citations · Full text
Martin Christner, Holger Rohde, Manuel Wolters et al. · Journal of Clinical Microbiology · 2010 · 304 citations · Full text
Agnès Ferroni, Stéphanie Suarez, Jean‐Luc Béretti et al. · Journal of Clinical Microbiology · 2010 · 278 citations · Full text