Journal of Hand Surgery (European Volume) · 2003 · 27 citations · 39 references
MedicineOrthopaedic SurgeryOrthopedic SurgeryBiomechanicsOrthopedic BiomechanicsOrthopedicsTendon InjuriesTendon MechanicsTendon RepairTendon SurgeryTendon BiomechanicsTendon Failure MechanicsTendon Injury MechanicsTensile LoadingTensile StrengthUltimate Strength AnalysisUltimate Strength AssessmentUltimate Tensile Strength
We performed a study to evaluate the tensile properties of partial tendon lacerations and the effects of peripheral sutures on the tendon strength. Seventy-two fresh pig flexor digitorum profundus tendons were divided equally into eight groups. Tendons in four of the groups were subjected to partial lacerations (60%, 70%, 80%, and 90%) and were not repaired. In the other four similar groups partial lacerations were repaired with running peripheral sutures. The tendons were subjected to load-to-failure tests in an Instron tensile machine to determine the initial, 1mm, 2mm gap formation forces and the ultimate strength. The tendons with lacerations of 80% and 90% had a remarkably lower tensile strength than those 60% and 70% lacerations. Running peripheral sutures increased the gap formation forces and the ultimate strength of all the tendons, though particularly those with 80% and 90% lacerations.
39
T. Kue Young · New England Journal of Medicine · 1973 · 903 citations
Flexor tendon forces: In vivo measurements
Frédéric Schuind, Marc García‐Elías, William P. Cooney et al. · The Journal Of Hand Surgery · 1992 · 491 citations
Natural Sciences, Orthopaedic Surgery, Orthopedic Surgery +13
AAOS, Symposium on Tendon Surgery in the Hand
Raymond M. Curtis · Annals of Surgery · 1976 · 234 citations · Full text