Parametric Investigation of Thrust Augmentation by Ejectors on a Pulsed Detonation Tube

Jack Wilson, Alexandru Sgondea, Daniel E. Paxson, Bruce N. Rosenthal

Journal of Propulsion and Power · 2006 · 58 citations · 26 references

DOIFull text

Open access

Concepts

Abstract

A parametric investigation has been made of thrust augmentation of a 1 inch diameter pulsed detonation tube by ejectors. A set of ejectors was used which permitted variation of the ejector length, diameter, and nose radius, according to a statistical design of experiment scheme. The maximum augmentations for each ejector were fitted using a polynomial response surface, from which the optimum ejector diameters, and nose radius, were found. Thrust augmentations above a factor of 2 were measured. In these tests, the pulsed detonation device was run on approximately stoichiometric air-hydrogen mixtures, at a frequency of 20 Hz. Later measurements at a frequency of 40 Hz gave lower values of thrust augmentation. Measurements of thrust augmentation as a function of ejector entrance to detonation tube exit distance showed two maxima, one with the ejector entrance upstream, and one downstream, of the detonation tube exit. A thrust augmentation of 2.5 was observed using a tapered ejector. Nomenclature bij = constants in Eq. (2) D = ejector diameter

References

26