Optometry and Vision Science · 1992 · 29 citations · 0 references
MedicineOphthalmologyVision ScienceNeuro-ophthalmologyOphthalmic SurgeryVisual OpticsContact Lens Clinical PracticeContact Lens OpticsRetinal SurgeryRigid Gas-permeable Contact LensesSoft Contact LensesSpectacle Lens OpticsLens DesignPolymethyl MethacrylateRetinal StabilizationRgp Lens DesignSpectacle Lens DesignStabilizationVision Through Contact Lenses
An optical device that produces partial stabilization of retinal images has been described. It consists of a high-plus spectacle lens used in combination with a large, high-minus, polymethyl methacrylate (PMMA) contact lens. This device is designed to provide more clear and stable vision in patients with acquired nystagmus due to neurological disease. We report success in using a smaller, rigid, gas permeable (RGP) contact lens that achieves the required degree of stabilization, but is more comfortable for patients than the PMMA contact lens originally described. We have confirmed that the degree of retinal image stabilization is similar to that achieved with the PMMA lens. We present a case report to illustrate its use.