Journal of Heat Transfer · 1980 · 94 citations · 0 references
EngineeringMechanical EngineeringFluid DynamicsHeat TransferTransport PhenomenaHeat FlowHeat Transfer AnalysisHeat Transfer FundamentalsHeat Transfer In FluidsHeat Transfer ModelingCylinder Wall Heat TransferElectrical BreakdownExperimental Study DesignFilm Breakdown MechanismsFilm FlowHeat Flux AnalysisLiquid Film BehaviorSurface Film Breakdown
In this study, an experimental investigation was conducted with subcooled water film flowing over an electrically heated horizontal cylinder. The combinations of film flow rate and heat flux at which film breakdown occurs (i.e., dry patches appear on the surface) were determined. At the conditions prior to dry patch formation, the heat transfer coefficient was determined as well. The results showed that the heat flux needed to cause a dry patch increases with film flow rate. Also, prior to dry patch formation, the heat transfer coefficient increases with film flow rate. The effects of the tube spacing and the liquid film inlet temperature on the breakdown heat flux and heat transfer coefficient were also studied.