Journal of Clinical Investigation · 1955 · 30 citations · 0 references
MedicineEndocrinologyNuclear MedicineDiagnostic Nuclear MedicineEndocrine Nuclear MedicineRadionuclide TherapyHyperthyroidism EvaluationRadioiodine TherapyRenal ScintigraphyThyroid EndocrinologyThyroid ScintigraphyThyroid Uptake StudiesThyroid Function EvaluationThyroid Function TestingThyroid Function Tests
In the preceding paper (1) mathematical equa-tions and numerical data were presented describ-ing the early movement of a test dose of radio-iodine in the human body. The information given can be used directly to calculate thyroidal uptake and renal excretion rate factors (or clear-ance rates) from observed values of the fractions of the net dose in the neck, N, and urine E, without the need for any blood samples, but the process is rather too tedious for routine use. However, the procedure can be greatly simplified by making suitable charts relating N and E to the thyroidal, ki, and renal, k2, rate factors for selectedfixed times t after injecting the test dose. Fixed time schedules are necessary because other-wise a large number of charts is required. For convenience the pertinent equations from the preceding paper (1) are repeated below: k = k1 +k2 (1)