Rubber glove tourniquet: perhaps not so simple or safe?

H.L. de Boer, Peter Houpt

European Journal of Plastic Surgery · 2007 · 15 citations · 1 references

DOIFull text

Open access

Concepts

Abstract

A bloodless field is essential in hand surgery. In finger surgery, this can be achieved by the rubber glove technique. When treating a tip avulsion in a 5-year-old boy the tourniquet was accidentally left in place. This resulted in a necrotic finger that had to be amputated. To prevent this disastrous complication, we propose never to use this method of digital tourniquet.

References

1