Structural Concrete · 2008 · 65 citations · 7 references
ArchitectureCivil EngineeringMaterials EngineeringBuilding MaterialsConstruction TechnologyStructural MaterialsConcrete ConstructionConcrete MaterialsConcrete TechnologyAggregate ShrinkageCompressive StrengthConcrete StrengthGroutsTensile StrengthUnconfined Compression TestUnconfined Compression TestingUnconfined Compressive Strength
The objective of this paper was to study the manufacture of suitable grouts for two-stage (pre-placed aggregate) concrete using different admixtures to improve flowability of grout and hence the strength of two-stage concrete. The hypothesis of two-stage concrete is different from conventional concrete, because the particle-to-particle contact of coarse aggregate shrinkage is lower than that of normal concrete. The most important aspect of two-stage concrete strength still remains unclear. The strength of two-stage (pre-placed aggregate) concrete has been described in different ways, by experiment or theory. As no reliable data are available showing the strength of two-stage (pre-placed aggregate) concrete, it was necessary to investigate its strength at different mixes. This paper deals with the effect of different types of admixture on the concrete strength of two-stage (pre-placed aggregate) concrete. The paper also presents experimental results of pre-placed crushed aggregate concrete using 36 different grout mixture proportions. A total of 360 standard concrete cylinders were tested in unconfined compression and tensile strength at 28 days. On the basis of these results, a relationship between the tensile strength and compressive strength of two-stage (pre-placed aggregate) concrete has been statistically derived.
7