Journal of Hematotherapy & Stem Cell Research · 2002 · 62 citations · 29 references
Life SciencesCell BiologyApoptosisCell TherapyStem Cell TransplantationCell DeathGraft SurvivalAnnexin V AssaysAnnexin V ImagingApoptosis After FreezingCell Death AssaysClonogenic PotentialEarly Apoptotic MarkersFlow Cytometric AnalysisFlow Cytometry Immunophenotyping
Quality assessment of stem cell grafts is usually performed by flow cytometric CD34(+) enumeration or assessment of clonogenic output of fresh material. Previously, we identified the occurrence of early apoptosis, not detectable with the permeability marker 7-amino actinomycin D (7-AAD), in purified frozen-thawed CD34(+) cells, using the vital stain Syto16. Syto(high)/7-AAD(-) cells were defined as viable, Syto16(low)/7-AAD(-) cells as early apoptotic and Syto16(low)/7-AAD(+) as dead. This was confirmed in a subsequent study using frozen-thawed transplants of lymphoma patients. In the present study on grafts from multiple myeloma and lymphoma patients, we investigated the functional consequences of the early apoptotic process. The mean Syto16-defined viability was 41 and 42%, respectively, for both graft groups, compared to 78% and 72%, respectively, using 7-AAD only. The established early apoptosis marker annexin V missed roughly 50% of the early apoptosis detected with Syto16. In contrast, viability of CD34(+) cells in nonmanipulated whole blood transplants from a matched group of lymphoma patients, after 72 h of storage at 4 degrees C, was more than 90%, even with the Syto16 assay. CFU recovery (median 26-33%) after cryopreservation matched CD34(+) recovery after Syto16, but not 7-AAD correction. In contrast, colony-forming unit (CFU) recovery in the whole blood transplant was close to 100%. Furthermore, early apoptotic CD34(+) cells had lost migratory ability toward stromal cell derived factor-1alpha (SDF-1alpha). The establishment of a Syto16(high)/7-AAD(-) proportion of CD34(+) cells offers a new approach for a more correct determination of the number of viable nonapoptotic CD34(+) cells in stem cell grafts. Further development of this assay should allow its incorporation into the routine CD34(+) assessment of post-thawed samples in clinical flow cytometry laboratories.
29
Angela Joyce · Paediatric Care · 1989 · 3.4K citations
Medicine, Hematology, Pediatrics +11
The Medical Journal of Australia · 1999 · 3.4K citations
The ISHAGE Guidelines for CD34+ Cell Determination by Flow Cytometry
D. Robert Sutherland, Lori Anderson, M. Keeney et al. · Journal of Hematotherapy · 1996 · 1.3K citations
Single platform flow cytometric absolute CD34+ cell counts based on the ISHAGE guidelines
Michael Keeney, Ian Chin‐Yee, Jan Popma et al. · Cytometry · 1998 · 486 citations · Full text
Medicine, Cell Biology, Hematology +16