Journal of Hydraulic Engineering · 2006 · 155 citations · 21 references
EngineeringCivil EngineeringBridge EngineeringStructural EngineeringSubsea EngineeringBridge ConstructionBridge DesignScour ControlBridge Pier ScourBridge ScourEfficiencyLocal ScourPier Geometry EffectsScourScour AnalysisScour Protection Design
The study investigates using independent and continuous pier collars with riprap to reduce local scour around bridge pier groups. The authors evaluated collar efficiency through laboratory experiments and compared the results with previous studies on single piers and pier groups without collars. Experiments showed that continuous collars with riprap cut scour by 50–60% on front and rear piers, independent collars outperformed continuous collars for two piers in line, rectangular piers aligned with flow benefited most, and collars were less effective around two transverse piers.
The present study examines the use of independent and continuous pier collars in combination with riprap for reducing local scour around bridge pier groups. The efficiency of collars was studied through experiments. The data from the experiments were compared with data from earlier studies on single piers with collars and bridge pier groups without collars. The data showed that in the case of two piers in line, combination of continuous collars and riprap results in the most significant scour reduction of about 50 and 60% for the front and rear piers, respectively. In other cases for two piers in line, independent collars showed better efficiency than a continuous collar around both piers. It was also shown that efficiency of collars is more on a rectangular pier aligned with the flow than two piers in line. Experiments however, indicated that collars are not so effective in reduction of scouring around two transverse piers.
21