Medical Physics · 2011 · 44 citations · 49 references
EngineeringBiomedical EngineeringPhysicsComputational Fluid DynamicsDiagnostic ImagingFluid DynamicsHemodynamicsVascular ImagingAneurysmal FlowBifurcation Aneurysm SurgeryBifurcation Flow DynamicsCfd SimulationComputational Fluid Dynamics ValidationFlow Field VisualizationSpatial VelocityVascular Flow Velocity Measurement
PURPOSE: Our purpose was to compare quantitatively velocity fields in and around experimental canine aneurysms as measured using an accelerated 4D PC-MR angiography (MRA) method and calculated based on animal-specific CFD simulations. METHODS: Two animals with a surgically created bifurcation aneurysm were imaged using an accelerated 4D PC-MRA method. Meshes were created based on the geometries obtained from the PC-MRA and simulations using "subject-specific" pulsatile velocity waveforms and geometries were then solved using a commercial CFD solver. Qualitative visual assessments and quantitative comparisons of the time-resolved velocity fields obtained from the PC-MRA measurements and the CFD simulations were performed using a defined similarity metric combining both angular and magnitude differences of vector fields. RESULTS: PC-MRA and image-based CFD not only yielded visually consistent representations of 3D streamlines in and around both aneurysms, but also showed good agreement with regard to the spatial velocity distributions. The estimated similarity between time-resolved velocity fields from both techniques was reasonably high (mean value >0.60; one being the highest and zero being the lowest). Relative differences in inflow and outflow zones among selected planes were also reasonable (on the order of 10%-20%). The correlation between CFD-calculated and PC-MRA-measured time-averaged wall shear stresses was low (0.22 and 0.31, p < 0.001). CONCLUSIONS: In two experimental canine aneurysms, PC-MRA and image-based CFD showed favorable agreement in intra-aneurismal velocity fields. Combining these two complementary techniques likely will further improve the ability to characterize and interpret the complex flow that occurs in human intracranial aneurysms.
49
The rician distribution of noisy mri data
Hákon Guðbjartsson, Samuel Patz · Magnetic Resonance in Medicine · 1995 · 2.5K citations
CURATIVE ENDOVASCULAR RECONSTRUCTION OF CEREBRAL ANEURYSMS WITH THE PIPELINE EMBOLIZATION DEVICE
Pedro Lylyk, Carlos Miranda, Rosana Ceratto et al. · Neurosurgery · 2009 · 803 citations
Medicine, Neurosurgery, Surgery +14
Magnitude and Role of Wall Shear Stress on Cerebral Aneurysm
Masaaki Shojima, M. Oshima, Kiyoshi Takagi et al. · Stroke · 2004 · 785 citations
Cardiovascular Flow Measurement with Phase-Contrast MR Imaging: Basic Facts and Implementation
Joachim Lotz, Christian Meier, Andreas Leppert et al. · Radiographics · 2002 · 659 citations
Medicine, Cardiology, Radiology +16