Medical Physics · 2008 · 34 citations · 10 references
EngineeringMaterials ScienceNuclear EngineeringNuclear MaterialsRadiation PhysicsRadiation ShieldingAbsorbed DoseConcrete ShieldingMedical Radiation ShieldingRadiation TherapyShielding DesignShielding MaterialsBarrier Thickness CalculationBaryte ConcreteBroad Beam ShieldingMonte Carlo Shielding SimulationRadiation Shielding CalculationsRadiation Transmission Through LeadShielding In BrachytherapyTenth-value Layer
To address the limited availability of radiation shielding data for brachytherapy as well as some disparity in existing data, Monte Carlo simulation was used to generate radiation transmission data for 60Co, 137CS, 198Au, 192Ir 169Yb, 170Tm, 131Cs, 125I, and 103pd photons through concrete, stainless steel, lead, as well as lead glass and baryte concrete. Results accounting for the oblique incidence of radiation to the barrier, spectral variation with barrier thickness, and broad beam conditions in a realistic geometry are compared to corresponding data in the literature in terms of the half value layer (HVL) and tenth value layer (TVL) indices. It is also shown that radiation shielding calculations using HVL or TVL values could overestimate or underestimate the barrier thickness required to achieve a certain reduction in radiation transmission. This questions the use of HVL or TVL indices instead of the actual transmission data. Therefore, a three-parameter model is fitted to results of this work to facilitate accurate and simple radiation shielding calculations.
10
RADIONUCLIDE AND RADIATION PROTECTION DATA HANDBOOK 2002
Dominique L. Delacroix, J Guerre, Philippe Leblanc et al. · Radiation Protection Dosimetry · 2002 · 242 citations