Chemical Engineering Communications · 2001 · 14 citations · 9 references
EngineeringMechanical EngineeringHeat TransferThermodynamicsTransport PhenomenaHeat ExchangersHeat FlowHeat Transfer AnalysisHeat Transfer In FluidsConvective Heat TransferFlow Through Heat ExchangersHeat Exchanger DesignHeat Exchanger PerformanceHeat Exchanger Performance AnalysisHeat Transfer Coefficient CorrelationsHeat Transfer Coefficient EstimationHeat Transfer Coefficients
Abstract Airside performance for tube bank having N = 1 ~6 are reported in this study. Test results indicated that the heat transfer coefficients for N = 1 and N = 2 are comparable and the heat transfer coefficients increase with the number of tube row. For the same P t, P t the heat transfer coefficients for the tube bank containing smaller diameter tube are higher than those of larger tube diameter for N≥2 and is comparable for N = 1. Comparisons of the heat transfer performance were made with several correlations. It is found that the Gnielinski correlation gives the best predictive ability. For multiple-row heat exchangers, the predictive ability of the well-known Žukauskas correlation is also good. But the correlation under-estimate the present I-row heat exchangers. As a consequence, a slight modification to the Žukauskas correlation is proposed that can extend its applicability in N = 1 and ReD < 1000. In addition, modification to the frictional performance of Žukauskas correlation is also made. The mean deviation of the proposed frictional correlation is 11.2%.
9
ASHRAE Handbook—1981 Fundamentals
Building Services Engineering Research and Technology · 1981 · 3.4K citations