Evaluation of Global and Regional Left Ventricular Function Using Two‐Dimensional and M‐Mode Echocardiography in Patients With an Automatic Implantable Cardioverter Defibrillator
10
Citations
9
References
1988
Year
The effects of glued epicardial patch electrodes of the automatic implantable cardioverter defibrillator on the left ventricular function was studied by two-dimensional and M-mode echocardiography in 15 patients. Pre- and postoperative end-diastolic and end-systolic left ventricular cross-sectional areas were evaluated using planimetry. Regional left ventricular wall motion at the level of the left ventricular patch electrode was analyzed by two end-diastolic and end-systolic perpendicular axes. Left ventricular end-diastolic and end-systolic diameters as well as E-point-septal-separation and fractional shortening were analyzed using M-mode echocardiography. The mean time interval between preoperative echocardiograms and implantation of the automatic defibrillator was 0.3 X 1.3 (less than 1-2) months. Postoperative echocardiograms were recorded 6.6 +/- 6.9 (0.5-24) months after implantation of the device. There were no significant differences between pre- and postoperative mean values of end-diastolic and end-systolic areas and axes as well as M-mode echocardiographic parameters. Our data show that left ventricular patch electrodes do not significantly alter global or regional left ventricular function in patients after implantation of the automatic defibrillator.