Real-Time Intraoperative Near-Infrared Fluorescence Angiography for Perforator Identification and Flap Design

Aya Matsui, Bernard T. Lee, Joshua H. Winer, Carrie Vooght, Rita G. Laurence, John V. Frangioni

Plastic & Reconstructive Surgery · 2009 · 39 citations · 5 references

Concepts

Abstract

Sir: The advent of perforator flap development marks an important paradigm shift in reconstructive surgery. Whereas anatomical landmarks serve to guide flap design, there exists a high degree of variability in vessel size and location. Preoperative methods of assessment described for evaluation of perforators include hand-held Doppler, color Duplex ultrasound, conventional angiography, high-resolution computed tomography, and magnetic resonance angiography. Despite these imaging studies, we still rely on clinical, intraoperative assessment of vessel size and flap perfusion. Our laboratory has previously developed a real-time, light-emitting diode–based imaging system that exploits invisible near-infrared light to assess the physiology of tissue while providing simultaneous color video imaging of the surgical field.1,2 Using this technology, we can assess the perforating vessels with near-infrared fluorescence angiography using indocyanine green, a U.S. Food and Drug Administration–approved near-infrared fluorophore. This permits patient-specific planning, image-guided creation, and intraoperative assessment without the need for lasers or ionizing radiation. The near-infrared fluorescence imaging system is positioned over the surgical field, with a working distance of 18 inches above the subject. White (400 to 650 nm) light and near-infrared fluorescence excitation (745 to 779 nm) light are produced using light-emitting diodes. Color video and near-infrared fluorescence images are acquired simultaneously and refreshed up to 15 times per second. The system is controlled hands-free with a foot switch, motorized lens on an articulated arm, and multifunction data-acquisition board.2 Twenty abdominal perforator flaps based on the deep superior epigastric vessels were evaluated in 20 anesthetized 35-kg Yorkshire pigs. Animals were studied under supervision of an approved institutional protocol. Indocyanine green was injected as a bolus through a central venous line. Near-infrared fluorescence exposure time was 67 msec, with images stored to hard disk every 500 msec before and after injection. Fluorescence intensity of the perforating arteries was selected as a region of interest and quantified. The contrast-to-noise-ratio was calculated as well. A single indocyanine green injection permitted localization and evaluation of the perforators (Fig. 1). In all cases, the location and distribution of perforators could be identified, before and after flap creation. The total time required for assessment was less than 1 minute, and repeated injections can be given every 10 minutes. Simultaneous acquisition of color video and near-infrared fluorescence permitted accurate, precise planning of flaps and image-guided assessment of flap perfusion.Fig. 1.: Dynamic near-infrared fluorescent contrast for flap design. Indocyanine green distribution and clearance during early arterial phase (8 seconds; above), late arterial phase (10 seconds; center), and venous phase (13 seconds; below). Ca, caudal; Cr, cranial; N, nipple; PA, perforating artery; SV, superficial vein.The use of indocyanine green angiography in reconstructive surgery has existed since 1995 to assess global flap perfusion.3 These imaging systems are rarely used, as they are laser-based, illuminate a small area, and provide black-and-white images. However, these studies have validated the excellent pharmacokinetic profile of indocyanine green and the high sensitivity of near-infrared fluorescence.3–5 The system we describe uses safe light-emitting diode light, permitting high sensitivity imaging over a 15-cm field of view without risk to subject or caregiver. The custom optics allow simultaneous acquisition of near-infrared fluorescence and color video images, as software provides a “merged” image of the two.1,2 With these tools, real-time intraoperative guidance is provided throughout the procedure and perforator flap design can be performed reliably. Presented as a poster at the Joint Molecular Imaging Conference, in Providence, Rhode Island, September 8 through 11, 2007. The first two authors contributed equally to this work. DISCLOSURE All intellectual property for the intraoperative near-infrared fluorescence imaging system is owned by Dr. Frangioni's employer, the Beth Israel Deaconess Medical Center, a teaching hospital of Harvard Medical School. The patent rights have been licensed nonexclusively by the Beth Israel Deaconess Medical Center to GE Healthcare. As inventor of the technology, Dr. Frangioni may someday receive royalties if a product is developed. Dr. Frangioni has no real or deferred equity interests, whatsoever, in this, or any other technology. Dr. Frangioni does not consult for any company. GE Global Research sponsors research in Dr. Frangioni's laboratory. ACKNOWLEDGMENT This study was funded by grant R01-EB-005805 from the National Institutes of Health (National Institute of Biomedical Imaging and Bioengineering). Aya Matsui, M.D. Division of Hematology/Oncology Beth Israel Deaconess Medical Center Boston, Mass., and Division of Cancer Diagnostics and Therapeutics Hokkaido University Graduate School of Medicine Sapporo, Japan Bernard T. Lee, M.D. Division of Plastic and Reconstructive Surgery Beth Israel Deaconess Medical Center Boston, Mass. Joshua H. Winer, M.D. Department of Surgery Brigham & Women's Hospital Boston, Mass. Carrie S. Vooght, B.S. Division of Hematology/Oncology Beth Israel Deaconess Medical Center Boston, Mass. Rita G. Laurence, B.S. Division of Hematology/Oncology Beth Israel Deaconess Medical Center, and Department of Surgery Brigham & Women's Hospital Boston, Mass. John V. Frangioni, M.D., Ph.D. Division of Hematology/Oncology and Department of Radiology Beth Israel Deaconess Medical Center Boston, Mass.

References

5