Medical Physics · 2008 · 196 citations · 43 references
MedicineBiomedical EngineeringRadiation DetectionRadiation DosimetryRadiation MeasurementAbsorbed DoseDosimetry InstrumentationFilm DosimetryPhantom DosimetryPhoton DosimetryRadiation Dose MeasurementAbsolute Dose MeasurementDose Distribution CalculationsDose ResponseEnergy DependenceMedical Dosimetry ApplicationsPhoton Beam QualityPhoton Energy DependenceSensitometric Curve
This paper focuses on the accuracy, in absolute dose measurements, with GafChromicTM EBT film achievable in water for a 6 MV photon beam up to a dose of 2.3 Gy. Motivation is to get an absolute dose detection system to measure up dose distributions in a (water) phantom, to check dose calculations. An Epson 1680 color (red green blue) transmission flatbed scanner has been used as film scanning system, where the response in the red color channel has been extracted and used for the analyses. The influence of the flatbed film scanner on the film based dose detection process was investigated. The scan procedure has been optimized; i.e. for instance a lateral correction curve was derived to correct the scan value, up to 10%, as a function of optical density and lateral position. Sensitometric curves of different film batches were evaluated in portrait and landscape scan mode. Between various batches important variations in sensitometric curve were observed. Energy dependence of the film is negligible, while a slight variation in dose response is observed for very large angles between film surface and incident photon beam. Improved accuracy in absolute dose detection can be obtained by repetition of a film measurement to tackle at least the inherent presence of film inhomogeneous construction. We state that the overall uncertainty is random in absolute EBT film dose detection and of the order of 1.3% (1 SD) under the condition that the film is scanned in a limited centered area on the scanner and at least two films have been applied. At last we advise to check a new film batch on its characteristics compared to available information, before using that batch for absolute dose measurements.
43
Precise radiochromic film dosimetry using a flat-bed document scanner
Slobodan Dević, Jan Seuntjens, E Sham et al. · Medical Physics · 2005 · 569 citations
Radiochromic film for medical radiation dosimetry
Martin J Butson, Kaiyuan Yu, Tsang Cheung et al. · Materials Science and Engineering R Reports · 2003 · 341 citations
Dosimetric properties of improved GafChromic films for seven different digitizers
Slobodan Dević, Jan Seuntjens, György Hegyi et al. · Medical Physics · 2004 · 277 citations