Aesthetic Surgery Journal · 2012 · 76 citations · 25 references
MedicineBioengineeringSurgeryBiomaterialsImplant SurgerySurgical InstrumentationBreast AugmentationBreast SurgeryImplant ComplicationsImplant-associated InfectionSkin SafetySterile TechniqueBacterial Adhesion To Implant SurfacesBacterial Contamination AssessmentGel PlacementImplant Safety EvaluationImplant Surface ContaminationRevision Breast AugmentationRevision ImplantationSilicone Implants
BACKGROUND: Overt infection and biofilm formation resulting from breast augmentation are rare but serious problems that can lead to contracture and a need for revision surgery. The Keller Funnel is a medical device composed of a rip-stop nylon sleeve with a hydrophilic inner coating. One claim of the funnel is that it facilitates a "no touch" technique, thereby limiting contamination. To date, there are no data to support this claim. OBJECTIVES: The authors evaluate skin and breast parenchyma contamination with standard implantation techniques and the Keller funnel. METHODS: Insertion techniques were tested in two fresh cadavers. Smooth, round, moderate-plus silicone gel implants were placed for each experiment. To quantify the amount of skin contamination, a 2% w/v fluorescein paste was painted onto the cadaver thorax. After implantation, the implants were soaked in 250 mL of sterile water, and the fluorescence emission of the resulting solution was measured with an ultraviolet-visible spectrophotometer. To qualify the potential contamination from breast parenchyma, the cadaver breast tissue was swabbed with methicillin-sensitive Staphylococcus aureus, and the implant surfaces were cultured postimplantation. RESULTS: The funnel resulted in a 27-fold decrease in skin contact for all smooth gel implants (P = .00059). The amount of skin contact and potential contamination increased incrementally with increasing implant volume when either the funnel or digital implantation techniques were used. Bacterial contamination from breast parenchyma was two times more likely with the standard digital insertion technique (P = .06). CONCLUSIONS: The Keller funnel appears to significantly reduce the amount of skin contact and potential parenchyma contamination.
25
Complications Leading to Surgery after Breast Implantation
Sherine E. Gabriel, John E. Woods, W. Michael O’Fallon et al. · New England Journal of Medicine · 1997 · 447 citations · Full text
Medicine, Plastic Surgery, Surgery +15
Detection of Subclinical Infection in Significant Breast Implant Capsules
Aniko Pajkos, Anand K. Deva, Karen Vickery et al. · Plastic & Reconstructive Surgery · 2003 · 371 citations
Efficacy of Surgical Preparation Solutions in Shoulder Surgery
Gordon M Nuber, Stephen M. Gryzlo, Geoffrey S. Marecek et al. · Journal of Bone and Joint Surgery · 2009 · 298 citations
Neal Handel, J. Arthur Jensen, Quieten Black et al. · Plastic & Reconstructive Surgery · 1995 · 292 citations
Medicine, Plastic Surgery, Surgery +17