Publication | Closed Access
Diaphragm cell for high-temperature diffusion measurements. Tracer Diffusion coefficients for water to 363 K
174
Citations
0
References
1989
Year
EngineeringDiaphragm CellExperimental ThermodynamicsSelf-diffusion CoefficientsTransport PhenomenaThermophysicsThermodynamicsBiophysicsThermoanalytical MethodModified Diaphragm CellTracer Diffusion CoefficientsHeat TransferHigh-temperature Diffusion MeasurementsDiffusion ResistanceEnvironmental EngineeringPhysiologyTemperature MeasurementMass TransferThermal EngineeringChemical KineticsThermophysical Property
A modified diaphragm cell for diffusion measurements at high temperatures is described. It has been used to obtain tracer diffusion coefficients for 3HHO and H218O in water from 298 to 363 K. Where comparisons are available, the results are in good agreement with literature data. The data have been converted to self-diffusion coefficients of water and combined with existing data to provide a series of equations covering the temperature range 242–498 K.