Journal of Cataract & Refractive Surgery · 2011 · 52 citations · 24 references
MedicineSurgeryMicrosurgeryOphthalmic SurgeryPharyngeal SurgeryMinimally Invasive SurgeryTransoral Pharyngeal SurgeryAnterior Chamber DimensionsPhacoemulsification After Ocular TraumaPostoperative ComparisonTorsional Modes
PURPOSE: To compare the intraoperative performance and postoperative outcomes of 3 phacoemulsification machines that use different modes. SETTING: Kensington Eye Institute, Toronto, Ontario, Canada. DESIGN: Comparative case series. METHODS: This chart and video review comprised consecutive eligible patients who had phacoemulsification by the same surgeon using a Whitestar Signature Ellips-FX (transversal), Infiniti-Ozil-IP (torsional), or Stellaris (longitudinal) machine. RESULTS: The review included 98 patients. Baseline characteristics in the groups were similar; the mean nuclear sclerosis grade was 2.0 ± 0.8. There were no significant intraoperative complications. The torsional machine averaged less phacoemulsification needle time (83 ± 33 seconds) than the transversal (99 ± 40 seconds; P=.21) or longitudinal (110 ± 45 seconds; P=.02) machines; the difference was accentuated in cases with high-grade nuclear sclerosis. The torsional machine had less chatter and better followability than the transversal or longitudinal machines (P<.001). The torsional and longitudinal machines had better anterior chamber stability than the transversal machine (P<.001). Postoperatively, the torsional machine yielded less central corneal edema than the transversal (P<.001) and longitudinal (P=.04) machines, corresponding to a smaller increase in mean corneal thickness (torsional 5%, transversal 10%, longitudinal 12%; P=.04). Also, the torsional machine had better 1-day postoperative visual acuities (P<.001). CONCLUSIONS: All 3 phacoemulsification machines were effective with no significant intraoperative complications. The torsional machine outperformed the transversal and longitudinal machines, with a lower mean needle time, less chatter, and improved followability. This corresponded to less corneal edema 1 day postoperatively and better visual acuity.
24
Lens Opacities Classification System II (LOCS II)
L.T. Chylack · Archives of Ophthalmology · 1989 · 573 citations
Risk factors for corneal endothelial injury during phacoemulsification
Ken Hayashi, Hideyuki Hayashi, Fuminori Nakao et al. · Journal of Cataract & Refractive Surgery · 1996 · 365 citations
Medicine, Ophthalmology, Surgery +13
Torsional mode versus conventional ultrasound mode phacoemulsification
Yizhi Liu, Mingbing Zeng, Xialin Liu et al. · Journal of Cataract & Refractive Surgery · 2007 · 183 citations
Medicine, Ophthalmology, Surgery +15