In situ strain monitoring of fiber-reinforced polymers using embedded piezoresistive nanocomposites

Bryan R. Loyola, Valeria La Saponara, Kenneth J. Loh

Journal of Materials Science · 2010 · 89 citations · 42 references

DOIFull text

Open access

Concepts

TL;DR

FRP composites are highly susceptible to damage such as delamination, matrix cracking, and debonding, and conventional embedded sensors can act as defects that promote failure, whereas carbon‑nanotube thin films have been validated for piezoresistivity. This study proposes an alternative in‑situ strain monitoring technique using layer‑by‑layer CNT‑polyelectrolyte films on glass‑fiber weaves and aims to evaluate the strain‑sensing performance of films of varying thickness embedded in FRP specimens. The films were deposited on glass‑fiber weaves, embedded in FRP, and their electromechanical response was measured with two‑point probe resistance and impedance spectroscopy, followed by a cubic smoothing spline fitting compared to linear least‑squares. Cubic spline fitting better captures the strain sensitivities and their variation with strain, while DC resistance describes bulk response and EIS reveals inter‑nanotube behavior.

Abstract

Fiber-reinforced polymer (FRP) structures and components are highly susceptible to damage due to delamination, matrix cracking, inter-laminar fracture, and debonding, all of which have potential to cause catastrophic structural failure. While numerous sensing technologies have been developed and embedded in FRP composites for monitoring strain, they serve as defects and can promote damage formation and propagation. Thus, in this study, an alternative technique is proposed for in situ strain monitoring of FRP composites via layer-by-layer multi-walled carbon nanotube-polyelectrolyte thin films deposited directly upon glass fiber weaves. To date, these carbon nanotube-based thin films have been validated for their piezoresistivity. The objective of this study is to characterize the strain sensing performance of different thickness thin films deposited on glass fiber weaves and embedded in FRP specimens using time-domain two-point probe resistance and frequency-domain electrical impedance spectroscopy (EIS) measurements. From the experimental thin film electromechanical response, a new method for fitting using a cubic smoothing spline is implemented and is compared to linear least-squares fitting. The results show that the cubic spline fit is better suited for capturing the strain sensitivities (or gage factors) of these thin films within the time- and frequency-domains along with the variation of strain sensitivity with applied strain. The bulk resistance response is described by the DC resistance measurements, whereas the EIS measurements provide insight of the inter-nanotube response.

References

42