2013 · 18 citations · 7 references
EngineeringMarine EngineeringActuatorsFault ToleranceNaval ArchitectureActuator DesignActuator ReliabilityFault-tolerant ControlMagnetic ActuatorsRotary ActuatorsShip Motion ControlFault-tolerant ActuationFault-tolerant DesignFault-tolerant WindingsFractional Slot Winding DesignLinear Electric ActuatorsLinear Magnetic ActuatorsPermanent Magnet Linear MotorsStator Winding Design
The reliability is a key requirement in electric actuators to be used for moving ship control surfaces. This paper addresses a fault-tolerant design for an innovative naval actuator based on an inverter-fed permanent magnet linear synchronous motor. Due to the highly non-conventional actuator concept, a detailed FEM modeling approach is presented in this paper for comparison of different design solutions. A fault tolerant modular stator structure is proposed. The modular winding can be designed based on an integer-slots or fractional-slots concept. The two solutions are compared in this paper, considering encumbrance and thrusting force performances. The linear motion can be reverted to rotary motion through a prismatic-rotoidal joint for coupling to on board ship steering gears used to drive control surfaces (rudders, stabilizing fins). A drive prototype has been built and is presently under testing to assess and refine the results of the FEM modeling presented in the paper.
7
Linear electric actuators and generators
I. Boldea, S.A. Nasar · 2002 · 67 citations
Engineering, Electrical Engineering, Mechanical Engineering +16
F. Luise, Stefano Pieri, Mario Mezzarobba et al. · IEEE Transactions on Industry Applications · 2012 · 40 citations