Development of the Trilateral Flash Cycle System: Part 1: Fundamental Considerations

Ian K. Smith

Proceedings of the Institution of Mechanical Engineers Part A Journal of Power and Energy · 1993 · 128 citations · 6 references

Concepts

TL;DR

The global market for low‑grade heat recovery systems is about £1 billion per year, yet conventional power systems convert only 2.5 % of heat from 100 °C fluids and 8–9 % from 200 °C fluids. The study proposes an ideal trilateral cycle as the optimal method for extracting maximum work from single‑phase low‑grade heat sources. The trilateral flash cycle achieves this by heating a liquid and expanding vapor in two phases, using light hydrocarbons as preferred fluids, and has been analytically compared to simple Rankine cycles. When two‑phase expanders reach over 75 % adiabatic efficiency, the TFC can deliver up to 80 % more power than simple Rankine cycles for 100–200 °C streams, at roughly the same cost per unit output.

Abstract

The world market for systems for power recovery from low-grade heat sources is of the order of £1 billion per annum. Many of these sources are hot liquids or gases from which conventional power systems convert less than 2.5 per cent of the available heat into useful power when the fluid is initially at a temperature of 100° C rising to 8–9 per cent at an initial temperature of 200°C. Consideration of the maximum work recoverable from such single-phase heat sources leads to the concept of an ideal trilateral cycle as the optimum means of power recovery. The trilateral flash cycle (TFC) system is one means of approaching this ideal which involves liquid heating only and two-phase expansion of vapour. Previous work related to this is reviewed and details of analytical studies are given which compare such a system with various types of simple Rankine cycle. It is shown that provided two-phase expanders can be made to attain adiabatic efficiencies of more than 75 per cent, the TFC system can produce outputs of up to 80 per cent more than simple Rankine cycle systems in the recovery of power from hot liquid streams in the 100–200°C temperature range. The estimated cost per unit net output is approximately equal to that of Rankine cycle systems. The preferred working fluids for TFC power plants are light hydrocarbons.

References

6