Plasma Carbon Monoxide Levels inTerm Newborn Infants with Sepsis

Yuan Shi, Feng Pan, Huaqiang Li, Jie Pan, Shi-wen Qin, Dongbo Jiang, Chikao Shen

Neonatology · 2000 · 16 citations · 11 references

Concepts

Abstract

Carbon monoxide (CO) has been implicated as a new endogenously produced mediator similar to nitric oxide (NO). CO was measured in plasma samples from 7 term newborn infants with sepsis and from 30 healthy neonates. Plasma CO levels were significantly higher in the group with sepsis at the time of admission to the neonatal intensive care unit than in the healthy controls (p < 0.05). Moreover, the elevated plasma CO levels were significantly related to increased NO production, as indicated by plasma nitrite/nitrate levels (p < 0.05). The present study suggests that, in addition to NO, CO might be another important mediator taking part in the pathogenesis of neonatal sepsis.

References

11