American Review of Respiratory Disease · 1989 · 43 citations · 12 references
Life SciencesPhysiologyBiomechanicsPhysiological Systems ModelingVentilationCardiopulmonary Exercise TestingMechanical VentilationPulmonary MechanicsRespiratory BiomechanicsBreathing EffortMechanical Load AnalysisRespiratory ImpedanceRespiratory Muscle FatigueRespiratory Muscle MechanicsRespiratory System ResistanceVentilatory LoadWork Of Breathing
Abstract Two indices of the total mechanical load on the ventilatory muscles, i.e., the work per minute (W·min−1) and the inflation pressure time index (PTI), have been developed to better assess muscle energy demands and fatigue potential. However, the relationship of these two indices to the various individual determinants of load and to muscle energy demands and fatigue potential are not well understood. To investigate these relationships in a theoretical fashion, we first constructed a computer model to quantitate the magnitude and relative effects of changes in the ventilation component of load, i.e., alveolar ventilation demands ( a) and dead space volume (Vd), and changes in the respiratory system impedance component of load, i.e., compliance (Crs) and resistance (Raw), on W·min−1 and PTI over a wide, clinically relevant, range of ventilatory conditions. From this analysis, we demonstrated that: (1) high mechanical loads could be developed over a wide range of circumstances (i.e., W·mirr−1 ranged from 0.29 kg·m·min−1 to 30.55 kg·m·min−1 and PTI ranged from 1.22 to 28.8 cm H2O as ventilation increased from 7 to 39 L·mirr−1 and impedances worsened from normal to a combined restricted and obstructed pattern); (2) each load determinant (i.e., a, Vd, Crs, and Raw) contributed substantially to these two indices of total mechanical load; (3) although impedance changes had comparable effects on W·min−1 and PTI, ventilation changes, as would be expected, had a greater effect on W·min−1 than on PTI. Further analysis of these indices incorporated data from other skeletal muscle studies to demonstrate that the relationship between the ventilatory load indices and muscle energy demands depends on the characteristics of the muscle load. Specifically, these data suggest that W·min−1 /energy demand is highest under normal impedance conditions and falls under higher impedance conditions, whereas PTI/energy demand rises under higher impedance conditions. In addition to load-energy demand relationships, considerations of inherent muscle strength and endurance capabilities would also appear to be important in predicting ventilatory muscle fatigue from load calculations.
12
<i>Mechanics of Breathing in Man</i>
Arthur B. Otis, Wallace O. Fenn, Hermann Rahn · Journal of Applied Physiology · 1950 · 926 citations
Control of respiratory frequency
Jere Mead · Journal of Applied Physiology · 1960 · 506 citations
Clinical manifestations of inspiratory muscle fatigue
Carol Cohen, Gary L. Zagelbaum, D. R. Gross et al. · The American Journal of Medicine · 1982 · 501 citations
Fatigue of inspiratory muscles and their synergic behavior
C Roussos, Mark Fixley, D Gross et al. · Journal of Applied Physiology · 1979 · 258 citations