Transfusion · 2000 · 32 citations · 13 references
MedicineCardiologyHematologyBioavailabilityDrug ClearanceTransfusion MedicineBlood PreservationBlood Transfusion ManagementBlood Transfusion SafetyPotassium BalancePotassium HomeostasisRed Blood Cell TransfusionAllogeneic TransfusionExperimental Study DesignHyperkalemia TreatmentPhase Iii Clinical TrialsPotassium ReabsorptionPotassium RemovalProphylactic TransfusionTransfusion-related Adverse Reactions
BACKGROUND: Within the past 2 years, three cases of cardiac arrest just after rapid transfusion of RBCs preserved for over 7 days after 15-Gy irradiation were found. This severe complication caused transient hyperkalemia. To prevent potassium (K(+)) overload by RBC transfusion at the bedside, a K(+)-adsorption filter made of sodium polystyrene sulfonate was developed. STUDY DESIGN AND METHODS: After in vitro and animal safety and efficacy tests, a Phase III clinical trial was conducted with 65 patients given transfusions via the newly developed filter (filter group) and 37 patients in whom the filter was not used (control group) and transfusions were given at twice the usual flow rate (20 mL/min). RESULTS: More than 85-percent (94.4+/-3.8%) removal of K(+) in RBCs in mannitol-adenine-phosphate (MAP) that had been preserved for more than 14 days or that were used 3 days after 15-Gy irradiation (calculated K(+): 3.8+/-1.3 mEq/bag) was achieved in 82 of 83 bags of MAP RBCs in the filter group, with 79.6 percent removed in the other, even in rapid transfusions. RBC recovery 1 day after transfusion, determined by increments in RBCs, Hb, and Hct, were 24 and 0.4 x 10(4) per microL, 0.7 and 0.3 g per dL, and 1.6 and 0 percent, respectively, in the filter and control groups. No adverse transfusion reactions, such as hypotension, anaphylactoid reactions, or asthma-like attacks, were observed, except for one case of urticaria in the filter group. Mild fever (within 1 degrees C) after transfusion was observed in both groups. Serologic markers of hemolysis rose slightly in both groups, but there was no significant difference between the two groups. CONCLUSION: The newly developed K(+)-adsorption filter is useful, especially in a rapid transfusion setting.
13
Neonatal mortality following transfusion of red cells with high plasma potassium levels
Tasha Hall, A. Barnes, Justin Miller et al. · Transfusion · 1993 · 161 citations
Medicine, Hematology, Physiology +17
Effect of irradiation on red cell cation content and transport
Carlo Brugnara, W. H. Churchill · Transfusion · 1992 · 85 citations
Some Properties of Blood Stored in Anticoagulant CPDA‐1 Solution. A Brief Summary
Gerald L. Moore, Carl C. Peck, P. R. Sohmer et al. · Transfusion · 1981 · 74 citations