Abstract

We can confirm the chance of achieving satisfactory results by CI even when the imaging of CVN is doubtful and the electrophysiological tests are disappointing. In our experience, a CI in Type IIb dysplasia of the CVN is a feasible option, provided that the candidate shows some responses at aided audiogram and at least minimal signs of language development. Adequate counseling is necessary for these children because the expected outcome is somewhat lower than that of their deaf peers with normal appearance of the nerves.