Journal of Hand Surgery (European Volume) · 2002 · 53 citations · 20 references
MedicineOrthopaedic SurgeryOrthopedic SurgeryElbow SurgeryOrthopedicsRheumatologyLower Extremity ReconstructionRheumatoid ArthritisTendon InjuriesTendon ReconstructionTendon RepairTendon SurgeryExtensor Tendon ReconstructionExtensor Tendon RuptureExtensor Tendon SurgeryGraftingLower Extremity Tendon ReconstructionPatient Satisfaction AnalysisPatient Satisfaction EvaluationUpper Extremity Tendon Reconstruction
We assessed the outcome of tendon grafting of multiple finger extensor tendon ruptures in 14 patients with rheumatoid arthritis. Extensor lags improved from a preoperative mean of 33 degrees (range, 20 degrees-65 degrees) to a postoperative mean of 18 degrees (range, 0-60 degrees). However, loss of finger flexion was observed, with a mean postoperative fingertip to palm distance of 1.6 (range: 0-7.5) cm. Patient satisfaction correlated with the fingertip to palm distance, though not with the postoperative extensor lag. Because of the loss of finger flexion which was probably due to muscle contracture, we conclude that the results of tendon grafts in this situation are unsatisfactory.
20