Clinical Orthopaedics and Related Research · 2004 · 72 citations · 19 references
Life SciencesMicrobiologyOrthopaedic SurgeryBacteriologyDiagnostic MicrobiologyMedical MicrobiologyBacterial InfectionsBone InfectionsClinical BacteriologyDiagnostic BacteriologyJoint InfectionsOrthopedic InfectionAseptic Loosening AssessmentBacterial DetectionJoint Replacement InfectionMicrobiologic DiagnosisPcr-based DetectionPolymerase Chain Reaction (Pcr)-based IdentificationSynovial Fluid MicrobiologyThreshold-based Detection
Identifying low-grade infection in failed total hip arthroplasties is an important but difficult task. This study investigated the ability of the polymerase chain reaction to identify low-grade infection during revision of total hip arthroplasties that failed from aseptic causes. One hundred thirteen specimens from 31 total hip arthroplasties revised for aseptic loosening were compared with 105 control specimens from 28 primary total hip arthroplasties. All surgeries were done in laminar flow operating rooms. No primary or revision specimen had positive microbiologic cultures. No revision specimen had histologic evidence suggestive of infection. Using the polymerase chain reaction with a detection threshold of 10 organisms per cubic centimeter of specimen, bacterial DNA was identified in 39 of 85 revision tissue specimens (46%) compared with 18 of 84 primary tissue specimens (21.4%). Bacterial DNA was identified in the synovial fluid of three specimens taken from 28 revision total hip arthroplasties (10.7%) and in two specimens taken from 21 primary total hip arthroplasties (9.5%). As multiple specimens were sent for each hip, a maximum of 16 of 31 revision total hip arthroplasties (52%) and eight of 28 primary total hip arthroplasties (29%) were considered to be infected. Bacterial DNA can be found in many specimens obtained from revised total hip arthroplasties considered to be aseptically loose. Because bacterial DNA identified at primary total hip arthroplasty was assumed to be attributable to contamination rather than present in healthy tissues, the overall specimen contamination rate of 19% and case contamination rate of 29% indicate that the polymerase chain reaction has poor specificity at this sensitivity level for diagnosing infection in revision total hip arthroplasty.
19
Rapid and simple method for purification of nucleic acids
René Boom, C. J. A. Sol, M M Salimans et al. · Journal of Clinical Microbiology · 1990 · 5.3K citations · Full text
Deep wound sepsis following total hip arthroplasty
R. Anne Fitzgerald, DR Nolan, DM Ilstrup et al. · Journal of Bone and Joint Surgery · 1977 · 481 citations
Michael M. Tunney, Sheila Patrick, Martin D. Curran et al. · Journal of Clinical Microbiology · 1999 · 454 citations · Full text
J.P. Hodgkinson, P. SHELLEY, B. M. Wroblewski · Clinical Orthopaedics and Related Research · 1988 · 374 citations