Electroanalysis · 2013 · 14 citations · 22 references
Natural SciencesChemistryToxicologyAnalytical ChemistryAnalytical ToxicologyElectroanalytical MethodsEnvironmental Analytical ChemistryInstrumental AnalysisAnalytical Speciation AnalysisAqueous Plant ExtractsLimit Of Quantification DeterminationQuantification Limit AnalysisQuantification Limit AssessmentSpeciation AnalysisThallium Analytical DetectionThallium Speciation
Abstract A sensitive voltammetric method (DPASV) was developed for the determination of Tl(I) and Tl(III) in plant extracts. To limit the influence of the organic matrix on the measurements, UV irradiation and addition of Amberlite XAD‐7 resin was studied. The application of 0.5 g of the resin allowed defining thallium speciation in 10.0 mL of a solution containing 0.20 mL of Sinapis alba extract. The quantification limit of 0.5 ng mL −1 Tl(I) was found for only 10 min of preconcentration, and is low enough to allow dilution of the sample before thallium determination. The procedure was validated using the recovery study and intermethod comparison with HPLC ICP MS.
22