Natural SciencesEnvironmental EngineeringEnvironmental SciencesEnvironmental MonitoringRadiation ProtectionRadiation SafetyAir PollutantsAir QualityEnvironmental ContaminantsExposure AssessmentExposure MonitoringRadioactive PollutionOccupational Exposure ManagementRadon Background MeasurementRadon Exposure RiskRadon MeasurementRadon MonitoringRadon Risk AssessmentTemporal VariabilityTrack Detectors
Water-plant operators may be exposed to high airborne radon-222 (222Rn) concentrations created when 222Rn gas transfers from water to air during the water treatment processes. To evaluate this hazard, we placed yearlong alpha-track radon detectors in 31 water plants. The geometric mean of the annual average airborne 222Rn concentrations was 3.4 pCi L-1 (126 Bq m-3), with a maximum of 133 pCi L-1 (4921 Bq m-3). We assessed the short-term temporal variability of 222Rn by monitoring four water plants continuously for a 3- to 6-day period. Cumulative working level months were estimated for the time workers were in the water plants. Because airborne 222Rn concentrations in water plants can reach levels considered unsafe for underground miners, it would be prudent to monitor airborne 222Rn concentrations in water plants which aerate water as part of their treatment process.
8
Potable Water As a Source of Airborne 222Rn in U.S. Dwellings
William W. Nazaroff, S. M. Doyle, A.V. Nero et al. · Health Physics · 1987 · 80 citations
Public Health, Environmental Engineering, Environmental Sciences +12
Spatial and Temporal Indoor Radon Variations
Daniel J. Steck · Health Physics · 1992 · 54 citations