Journal of Composites for Construction · 2015 · 115 citations · 20 references
EngineeringMaterials EngineeringMaterials ScienceBuilding MaterialsStructural EngineeringStructural MaterialsComposite MaterialsConcrete ConstructionConcrete MaterialsConcrete TechnologyFiber-reinforced CompositesReinforced Concrete StructuresAxial CompressionAxial StrainCompressive StrengthConcrete Compressive StrengthFailure ModesFiber-reinforced Polymer CompositesFiber-reinforced Polymer WrappingReference Specimens
This study investigates the behavior and failure modes of fiber-reinforced polymer (FRP) confined concrete wrapped with different FRP schemes, including fully wrapped, partially wrapped, and nonuniformly-wrapped concrete cylinders. By using the same amount of FRP, this study proposes a new wrapping scheme that provides a higher compressive strength and strain for FRP-confined concrete, in comparison with conventional fully wrapping schemes. A total of 33 specimens were cast and tested, with three of these specimens acting as reference specimens and the remaining specimens wrapped with different types of FRP (CFRP and GFRP) by different wrapping schemes. For specimens that belong to the descending branch type, the partially-wrapped specimens had a lower compressive strength but a higher axial strain as compared to the corresponding fully-wrapped specimens. In addition, the nonuniformly-wrapped specimens achieved both a higher compressive strength and axial strain in comparison with the fully-wrapped specimens. Furthermore, the partially-wrapping scheme changes the failure modes of the specimens and the angle of the failure surface. A new equation that can be used to predict the axial strain of concrete cylinders wrapped partially with FRP is proposed.
20