Physics in Medicine and Biology · 2009 · 18 citations · 14 references
MedicineOncologyRadiation OncologyClinical Radiation OncologyRadiation DosimetryTreatment PlanningIntensity-modulated RadiotherapyPatient-specific DosimetryRadiation TherapyRadiation Treatment PlanningTreatment Planning Dose CalculationTreatment Planning PhysicsIntensity Modulated Radiation Therapy Dose CalculationIntensity-modulated Radiation Therapy DosimetryIntensity-modulated Radiotherapy Dose DistributionMotion-corrected DosimetryOrgan Motion ModelingTumor Dose DistributionTumor Motion AnalysisVariances
In their classic paper, Yu et al (1998 Phys. Med. Biol. 43 91) investigated the interplay between tumor motion caused by breathing and dynamically collimated, intensity-modulated radiation delivery. The paper's analytic model assumed an idealized, sinusoidal pattern of motion. In this work, we investigate the effect of tumor motion based on patients' breathing patterns for typical tomotherapy treatments with field widths of 1.0 and 2.5 cm. The measured breathing patterns of 52 lung- and upper-abdominal-cancer patients were used to model a one-dimensional motion. A convolution of the measured beam-dose profiles with the motion model was used to compute the dose-distribution errors, and the positive and negative dose errors were recorded for each simulation. The dose errors increased with increasing motion magnitude, until the motion was similar in magnitude to the field width. For the 1.0 cm and 2.5 cm field widths, the maximum dose-error magnitude exceeded 10% in some simulations, even with breathing-motion magnitudes as small as 5 mm and 10 mm, respectively. Dose errors also increased slightly with increasing couch speed. We propose that the errors were due to subtle drifts in the amplitude and frequency of breathing motion, as well as changes in baseline (exhalation) position, causing both over- and under-dosing of the target. The results of this study highlight potential breathing-motion-induced dose delivery errors in tomotherapy. However, for conventionally fractionated treatments, the dose delivery errors may not be co-located and may average out over many fractions, although this may not be true for hypofractionated treatments.
14
The management of respiratory motion in radiation oncology report of AAPM Task Group 76a)
Paul Keall, G Mageras, James M. Balter et al. · Medical Physics · 2006 · 2.3K citations · Full text
Effects of motion on the total dose distribution
Thomas Bortfeld, Steve Jiang, Eike Rietzel · Seminars in Radiation Oncology · 2004 · 353 citations
Novel breathing motion model for radiotherapy
Daniel A. Low, Parag J. Parikh, Wei Lü et al. · International Journal of Radiation Oncology*Biology*Physics · 2005 · 204 citations